Part Number Hot Search : 
MBR30 74LS169 MOC8103 BT440 KBP2005 C5032 CT520 2M100
Product Description
Full Text Search
 

To Download 37830 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  15 electrical connection dimensions indication/operating means features model number masters and gateways subject to reasonable modifications due to technical advances. copyright pepperl+fuchs, printed in germany pepperl+fuchs group  tel.: germany (06 21) 7 76-0  usa (330) 4 25 35 55  singapore 7 79 90 91  internet http://www.pepperl-fuchs.com date of issue 21.01.2002 terminal for wall mounting 107 93 114 60  stand-alone master with plc func- tionality  two-digit lc display  voltage supply from as-interface  automatic baud rate detection  programmable slave addresses  display of detected slaves  fault diagnosis  parameterisation and monitor soft- ware  power rail connection  rs 232 interface power rail screen sub-d socket 4 5 as-i - as-i + as-i + as-i - as-i + as-i - 24 23 33 32 5 4 3 2 5 25 26 27 35 36 rxd txd gnd rxd txd gnd rs 232 vam-ctr-kf-r2 mode set prg enable prj mode config err asi active ser active power u asi rs 232 123 4 8 56 7 9 29 28 34 30 31 32 33 35 36 20 19 25 21 22 23 24 26 27 11 10 16 12 13 14 15 17 18 as-interface master rs 232 cabinet module as-interface master vam-ctr-kf-r2
16 technical data vam-ctr-kf-r2 documentation software masters and gateways subject to reasonable modifications due to technical advances. copyright pepperl+fuchs, printed in germany pepperl+fuchs group  tel.: germany (06 21) 7 76-0  usa (330) 4 25 35 55  singapore 7 79 90 91  internet http://www.pepperl-fuchs.com date of issue 21.01.2002 the documentation includes manuals in ger- man and english. it is available on the internet and in printed form as a cd-rom on request. general specifications as-i specification v2.0 interface interface type rs 232 transfer rate 1200 , 2400 , 4800 , 9600 , 19200 , 38400 or 57600 bit/s , automatic baud rate detection indicators/operating means lc display, two-digit address display, error message led as-i active as-i operation normal; led green led config err configuration error; led red led prg enable autom. programming; led green led energy voltage on; led green led prj mode projecting mode active; led yellow led ser active interface in operation; led green led u as-i as-i voltage; led green switch set selection and setting of a slave address button mode mode selection/saving the configuration electrical specifications insulation voltage u i ? 500 v rated operational voltage u e from as-interface rated operational current i e 150 ma connection type as-interface removable coded terminals, power rail ambient conditions ambient temperature 0 ... 55 c (273 ... 328 k) storage temperature -25 ... 70 c (248 ... 343 k) mechanical specifications protection degree ip20 in accordance with en 60529 mass 420 g function the vam-ctr-kf-r* is a stand-alone master with integrated plc functionality. the design of this master is ideal for use in a cabinet. its housing, only 60 mm wide, occupies little space in a cabinet installation. the vam-ctr-kf-r* is installed by snapping it onto the 35 mm din rail per en 50022, with the integrated power rail. the as-interface signal is transmitted th- rough conductors, which are integrated into the power rail. thus all cabinet modules in kf housing can be connected to the as-interface cable by simply snapping them onto the din rail. removable terminals for leading the as-i cable through the cabinet are available. these terminals are coded and allow "online" maintenance, i.e. while the system is under power. the connection to the as-interface power supply is established through these terminals which can also be used for the serial interface. a 9-pin sub-d connector is also available. power to the master is supplied by the as-i cable. two push buttons are used for address assignment of the as-interface slaves and accep- tance of the desired configuration. in configuration mode, all detected as-interface slaves are displayed on the 2-digit lcd. in normal operation, the lcd is blank unless the master detects a faulty as-interface slave. there are 7 leds on the front panel, showing the current status of the as-i line. plc functionality the vam-ctr-kf-r* provides 16 kbytes of program memory, 8 kbytes of main memory, 1024 counters and 1024 timers for plc functionality. these capacities suffice to process data on the as-interface. thus the master can also be operated in "stand-alone? mode. the program processing time is approximately 1000 word commands every 2 ms. the program- ming language is based upon the step5 ? programming language. the as-i control tools software is supplied as restricted version together with the documenta- tion. the software performs addressing, pro- gramming and monitoring of the as-interface network. in addition, it contains an editor that creates programs for the integrated plc func- tionality. the full version of the as-i control tool is available as an accessory and features an expanded diagnostics monitor as well as a larger program memory for as-i control which makes it possible to detect faulty telegrams of slaves. accessories vaz-sw-act32 full version of the as-i control tools upr-05 universal power rail including aluminium top hat section rail and cover, 2 m long upr-e end cap for upr-05 pr-05 power rail with grid, 0.5 m long


▲Up To Search▲   

 
Price & Availability of 37830

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X